Hs Incorporated Driver Download For Windows



In this post, we’ve managed to share you the Bundle of the Newest Qualcomm HS-USB QDLoader 9008 Driver for Windows 7,8/8.1, 10. This driver will use both 32 Bit & 64 Bit OS. We have also shared an in-depth tutorial for How to Install Qualcomm Driver or Installation them onto your Personal Computer running Windows OS. This package (QualcommQDLoaderHS-USBDriver64bitSetup.zip) contains Qualcomm HS-USB QDLoader 9008 Drivers for Windows 10/7/8/8.1 64-Bit OS. This Qualcomm QDLoader Driver helps in detecting the device when it is connected to PC in EDL Mode or Download Mode. QCA BT Driver for Windows 10 (64-bit).

USB-RS232 Serial Converter Driver DownloadHs Incorporated Driver Download For Windows

The package provides the installation files for FTDI USB Serial Converter Driver version 2.12.28. If the driver is already installed on your system, updating (overwrite-installing) may fix various issues, add new functions, or just upgrade to the available version. Canon U.S.A., Inc. And Canon Canada Inc. (collectively 'Canon') warrant to the original end-user purchaser, when delivered to you in new condition in its original container, that this PowerShot Digital Camera Product (the 'Product') will be free from defects in materials and workmanship under normal use and service for a period of one (1) year.

D-link sound cards & media devices driver download for windows 7. Windows 7 64-bit & 32-bit, Windows Vista 64-bit & 32-bit, Windows XP, Windows 2000, Windows Me, Windows 98

Important note regarding Windows 7 and Vista:
The driver MUST be installed 'as Administrator'
Right-click the downloaded EXE file and choose Run as administrator

Download the Windows installer for the USB RS-232 adaptor:
Download for Windows 7/Vista/XP (32-bit)
Download for Windows 7/Vista (32-bit and 64-bit)

If for some reason the above driver does not work, try one of the following:
Download for Windows 7/Vista/XP (32-bit and 64-bit - Alternate driver)
Download for Windows XP, 2000, 98/ME (32-bit only)

For older cables (purchased prior to October, 2010):
Download for Windows 7/Vista/XP (32-bit and 64-bit)
Download for Windows Vista (32-bit only)

Run the installer, then after rebooting, plug the USB end of the adapter into one of the USB ports on the computer.

NOTE: For Windows 7, please use RC build 7100 or RTM Final version. (Installer program will not run on early Windows 7 or Beta versions)

Check the software driver installation

1) Open the Device Manager dialog from Control Panel

  • Windows Vista: Start >> Control Panel >> System >> Hardware >> Device Manager
  • Windows XP: Start >> Control Panel >> System >> Hardware >> Device Manager
  • Windows 2000: Start >> Settings >> Control Panel >> System >> Hardware >> Device Manager
  • Windows 98/ME: Start >> Settings >> Control Panel >> System >> Device Manager

2) Click the plus sign (+) next to 'Ports'.

3) If the device is properly installed, 'Serialio.com USB Serial Port' or 'Prolific USB-to-Serial COM Port' will be displayed.


The software driver is properly installed, but the USB-RS232 adaptor does not work as expected

One of the common reasons that software may not work as expected with a USB-Serial adaptor when the devcie is properly installed, is many older programs (and even some new ones) only support a limited number of COM ports (e.g. only COM1 - COM4)

If the USB-RS232 adapter is installed as COM5, it may need to be reassigned to COM1 - COM4 to work with some software.

The following outlines how to to reassign the COM port on Windows XP/2K/Me/98SE

Windows XP

1) Follow steps 1-3 of 'Check the software driver installation'above.

2) Right-click on the 'Prolific USB to Serial Port', then click Properties

3) Click on the 'Port Settings' tab. Click the 'Advanced' button.

4) In the 'COM Port Number' drop-down select the desired port number. For example if the software requires COM2, select COM2. Note the COM port must have '(in use)' listed next to it, if it does then another device with that name is already installed in the system. After selecting the desire port number, click 'OK.'

5) Click 'OK' again, and the device will show up as being on the same COM port that it was before (i.e., COM5), but should show up on the selected port name when the Device Manager dialog is closed and opened again.

6) Close the Device Manager. Launch the software to use with the new COM port.

Windows 2000, Me, and 98 SE (Second Edition)

1) Follow steps 1 2 of 'Check the software driver installation'above.

2) Right-click on the 'Prolific USB to Serial Port', then click Properties.

3) Click on the 'Port Settings' tab. Click the 'Advanced' button.

4) Uncheck 'Use automatic settings'.

5) Select 'Input/Output range'. Click on 'Change Settings'.

Download

6) Type '02E8-02EF' in the Value box. This value will change the port to COM 4. If COM 4 is in use, you must choose another port. The values for each port are.

  • COM 1: 03F8-03FF
  • COM 2: 02F8-02FF
  • COM 3: 03E8-03EF
  • COM 4: 02E8-02EF

Hs Incorporated Driver Download For Windows 7

7) Enter the value, then click OK. Click OK again, then click Yes when the 'Creating a Forced Configuration' window appears. Click OK.

8) Restart the computer. The Device Manager can be checked, to see the COM port change.

Hs Incorporated Driver Download For Windows Xp

Note: Adaptor may not be exactly as pictured above.
back